SKU:

Battery Overshoot & Over-Discharge Protection Automatic Shutdown Switch Module
蓄电池过冲过放保护自动关断开关模块
条码:6922343642988
HSCode:90329000
批量修改原始型号
采购:Felix  编辑:Leah  产品经理:Maura


1. Charging mode IN: By setting the upper limit voltage UP and lower limit voltage dn; when the battery voltage is less than or equal to the lower limit voltage dn, the relay is turned on and the charger starts charging the battery; when the battery voltage is greater than or equal to the upper limit voltage UP, the relay is turned off and complete. One-time automatic charging; the relay is turned on and IN flashes, indicating that charging is in progress.
2. Discharge mode OUT: By setting the upper limit voltage UP and lower limit voltage dn; when the battery voltage ≥ the upper limit voltage UP, the relay is turned on and discharge starts; when the battery voltage is less than or equal to the lower limit voltage dn, the relay is turned off to complete an automatic discharge function; The relay is turned on and OUT flashes, indicating that it is discharging.
3. Charge/discharge time control function: When the set time parameter OP is non-zero, charge/discharge time control is started; when the relay is turned on to start a charge/discharge, the timing starts; when the timing is completed, the relay is automatically disconnected to complete a charge. /Discharge process; if the timing is completed, in charging mode, the detection voltage is less than the lower limit voltage dn or in discharge mode, the detection voltage is greater than the upper limit voltage UP, the charging time control function will be automatically turned off, and H:ER will flash to remind the user that the time parameter setting is incorrect. Reasonable; press any key to stop flashing
4. When charging/discharging time control is not turned on, the product will record a complete time. When entering the time display interface, the charging time will flash and display; it will be cleared when exiting the time display interface or the next charging is turned on (relay is turned on).
5. Automatic parameter detection: After setting the parameters and exiting, if the lower voltage limit dn ≥ the upper limit voltage up, the system will flash "ERR" as a reminder.
6. Discharge conduction forced start time FOP (0~10S): After the relay conduction conditions are met, the relay is forced to conduct (0~10S) and the battery voltage is detected again; this function is mainly for the discharge function, and some test loads are At the moment of conduction, it will be instantly pulled down to the lower limit voltage, causing the relay to be disconnected due to false triggering, and the normal discharge process cannot be carried out.
7. Dimensions: 62x57x22mm
8. Weight: 51 grams
9. Note: This product is a simple voltage controller that turns on and off the output through a relay. It only functions as a switch and cannot transform voltage.

1. 充电模式IN:通过设置上限电压UP、下限电压dn;当电池电压小于等于下限电压dn,继电器导通,充电器开始给电池充电;当电池电压大于等于上限电压UP,继电器断开,完成一次自动充电;继电器导通,IN闪烁,表示正在充电
2. 放电模式OUT:通过设置上限电压UP、下限电压dn;当电池电压≥上限电压UP,继电器导通,开始放电;当电池电压小于等于下限电压dn,继电器断开,完成一次自动放电功能;继电器导通,OUT闪烁,表示正在放电
3. 充电/放电时间控制功能:当设置时间参数OP 非零,启动充电/放电时间控制;当继电器导通开启一次充电/放电时,开始计时;当计时完成,自动断开继电器,完成一次充电/放电过程;如果计时完成,充电模式下,检测电压小于下限电压dn或放电模式下,检测电压大于上限电压UP,自动关闭充电时间控制功能,并闪烁显示 H:ER 提醒用户,时间参数设置不合理;按任意键停止闪烁
4. 在未开启充电/放电时间控制情况下,产品会记录一次完整时间,当进入时间显示界面,闪烁显示充电时间;再退出时间显示界面或下一次充电开启(继电器导通)时清空
5. 参数自动检测:当设置完参数,退出时,如果电压下限dn ≥上限电压up,系统会闪烁显示“ERR”以示提醒
6. 放电导通强制启动时间FOP(0~10S):满足继电器导通条件后,继电器强制导通(0~10S),再次检测电池电压;该功能主要是针对放电功能,有的测试负载在导通瞬间,会瞬间拉低到下限电压,误触发导致继电器断开,无法进行正常的放电过程
7. 尺寸:62x57x22毫米
8. 重量:51克
9. 注:此产品是简单的电压控制器,是通过继电器来开启和关断输出,只起到开关作用,不能变压
代码:

Specification:
Package weight
One package Weight 0.06kgs / 0.13lb
One Package Size 8.0cm * 8.0cm * 5.0cm / 3.15inch * 3.15inch * 1.97inch
Qty per Carton 144
Carton Weight 9.74kgs / 21.47lb
Carton Size 50cm * 34cm * 32cm / 19.69inch * 13.39inch * 12.6inch

代码: